87   Artículos

« Anterior     Página: 1 de 5     Siguiente »

 
en línea
Zhanzhong Yin, Hui Zhang and Wenwei Yang    
A steel plate shear wall often uses partially encased composite (PEC) columns instead of edge frame columns. Such a steel plate shear wall not only bears the gravity load of the structure and resists the bending moment caused by lateral force by taking a... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Zhenbang Ma, Yuntian Wu, Jie Zhang and Mao Zhang    
The coupled steel plate and reinforced concrete (C-SPRC) composite wall is a new type of coupled-wall system consisting of steel coupling beams (SCBs) that join two SPRC walls where the steel plate shear wall (SPSW) is embedded in the RC wall. Although t... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Mohammad Javad Moradi and Mohammad Amin Hariri-Ardebili    
There is a large amount of useful information from past experimental tests, which are usually ignored in test-setup for the new ones. Variation of assumptions, materials, test procedures, and test objectives make it difficult to choose the right model fo... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Daniel Howe, Chris E. Blenkinsopp, Ian L. Turner, Tom E. Baldock and Jack A. Puleo    
Robust measurements of bed shear stress under wave runup flows are necessary to inform beachface sediment transport modelling. In this study, direct measurements of swash zone bed shear stress were obtained in medium and prototype-scale laboratory experi... ver más
Revista: Journal of Marine Science and Engineering    Formato: Electrónico

 
en línea
Xun Zhang, Qiankun Liu, Weiwei Xiao, Fan Yu, Liming Cai and Lianzhi Song    
In this investigation, a U-shaped connection (U-C) was introduced for a prefabricated steel plate shear wall with beam-only connections. This design replaces a portion of shear bolts with tension bolts to enhance bolt efficiency and reduce the overall bo... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Niki Balkamou and George Papagiannopoulos    
Steel Plate Shear Walls (SPSW) provide significant lateral load capacity and can be utilized in the seismic retrofit and upgrade of existing reinforced concrete (r/c) buildings. In this study, the application of SPSW to retrofit a r/c building designed a... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Rahul Tarachand Pardeshi, Prakash Abhiram Singh, Yogesh Deoram Patil     Pág. 177 - 191
Revista: Advances in Technology Innovation    Formato: Electrónico

 
en línea
Jiakang Li, Zhe Zhang, Lu Wang, Zhe Ma and Wenyuan Wang    
Aiming at the problem of excessive vertical vibration caused by seismic primary waves in jacket structures located in seismic zones in China, a new type of shear plate metal damper with upper and lower elliptical openings (SPA) is proposed in this paper.... ver más
Revista: Journal of Marine Science and Engineering    Formato: Electrónico

 
en línea
Ramy I. Shahin, Mizan Ahmed and Saad A. Yehia    
This study aims to investigate the local elastic buckling behavior of simply-supported prismatic web plates under pure shear loading. Comprehensive finite element analysis is conducted to analyze the effects of various geometric parameters, such as taper... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Jianian He, Xuhao Li, Shizhe Chen and Huasheng Xian    
Many studies on structural topology optimization of steel plate shear walls have been conducted. However, research on topology optimization using the bidirectional evolutionary structural optimization method is limited. Accordingly, this study optimized ... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Flavia Bustos, Jorge Hinojosa and Víctor Tuninetti    
The computational modeling of hysteretic dampers is a powerful tool for design, allowing us to predict and optimize damper performance. In this research, a numerical model, based on Chaboche?s nonlinear kinematic hardening constitutive law, was implement... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Mohammad AlHamaydeh, Ahmed Mansour Maky and Mohamed Elkafrawy    
Modeling Steel Plate Shear Wall (SPSW) behavior can be computationally demanding. This is especially true when high-fidelity modeling is carried out via shell or 3D solid elements. It has been shown that SPSW behavior can be captured with adequate accura... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Sarat Chandra Mohapatra and C. Guedes Soares    
A hydroelastic model associated with the interaction between a surface wave and a floating circular structure connected with mooring lines in finite water depth is developed using BIEM. The BIEM solution is achieved using free surface Green?s function an... ver más
Revista: Journal of Marine Science and Engineering    Formato: Electrónico

 
en línea
Yudong Qiu, Zhan Wang, Jianrong Pan, Fangxin Hu, Shubham Sharma and Ahmed Farouk Deifalla    
Steel frame with steel plate shear walls (SPSWs) is used to resist lateral loads caused by wind and earthquakes in high-rise buildings. In this load-resisting system, the cost and performance are more efficient than in the moment frame system. Behaviors ... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Hadee Mohammed Najm, Amer M. Ibrahim, Mohanad Muayad Sabri, Amer Hassan, Samadhan Morkhade, Nuha S. Mashaan, Moutaz Mustafa A. Eldirderi and Khaled Mohamed Khedher    
In recent years, steel-concrete composite shear walls have been widely used in enormous high-rise buildings. Due to their high strength and ductility, enhanced stiffness, stable cycle characteristics and large energy absorption, such walls can be adopted... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Jianian He, Shuhong Lin, Yicheng Li, Xian Dong and Shizhe Chen    
Frame structures equipped with steel plate shear walls (SPSWs) have been widely used in high-rise buildings due to their good seismic performance. In this study, the strip model and combined strip model were used to analyze the performance of SPSWs. Furt... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Guiwen Liu, Jie Liu, Neng Wang, Xuanyi Xue and Youjia Tan    
Fire has significant effects on the residual resistance of steel structures. It is necessary to accurately clarify its effects on Q690 HSS plate girders, which have been widely used. In this paper, the ultimate resistance and effective service resistance... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Arsalan Majlesi, Hamid Asadi-Ghoozhdi, Omid Bamshad, Reza Attarnejad, Amir R. Masoodi and Mehdi Ghassemieh    
Steel plate shear walls usually do not satisfy the strong-column weak-beam design criteria, leading to larger column sections. On the other hand, rigid frame structures are typically constructed in low-rise to mid-rise buildings built in locations prone ... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Idris Bedirhanoglu    
One of the reasons that cause the collapse of buildings is deficient short columns, which need to be retrofitted to prevent the collapse of the building in a potential earthquake. External reinforced concrete (RC), steel plates, and fiber-reinforced poly... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Yimin Wang, Xiuxing Sang, Kaiguang Shang, Yushuo Zhang and Jinsan Ju    
The steel plate?concrete composite shear wall (SPCSW), having been widely applied to several super high-rise buildings, is currently regarded as a new type of lateral load-resisting structure. The SPCSW design does not consider the connection to the surr... ver más
Revista: Buildings    Formato: Electrónico

« Anterior     Página: 1 de 5     Siguiente »