|
|
|
Zhaohong Ye, Yue Sun, Xiufang Liu, Peiyue Wang, Chunsen Tang and Hailin Tian
|
|
|
|
|
|
|
Jiang Li, Wenzhen Wei, Shuo Zhang, Guoqing Li and Chenghong Gu
Micro phasor measurement units (μPMU) installed in active distribution networks are very useful for improving observability by acquiring system real-time data. However, three-phase imbalance and harmonic power flows adversely impact the accuracy of sy...
ver más
|
|
|
|
|
|
|
|
Ali Karami
Pág. 235 - 250
In this research, a two-stage identification-based approach is proposed to obtain a two-machine equivalent (TME) system of an interconnected power system for transient stability studies. To estimate the parameters of the equivalent system, a three-phase ...
ver más
|
|
|
|
|
|
|
Liying Huang, Dongyuan Qiu, Fan Xie, Yanfeng Chen and Bo Zhang
The stability issue of a single-phase two-stage grid-connected photovoltaic system is complicated due to the nonlinear v-i characteristic of the photovoltaic array as well as the interaction between power converters. Besides, even though li...
ver más
|
|
|
|
|
|
|
Indra Ferdiansyah, Era Purwanto, Novie Ayub Windarko
Pág. 237 - 258
This paper propose about using PID control system based on Kp, Ki, and Kd parameter determination with scheduling process from fuzzy logic. Control system is used to arrange speed of three phase induction motor using IFOC method. This method can be minim...
ver más
|
|
|
|
|
|
|
Othman Hasnaoui, Mehdi Allagui
The main causes of wind farms disconnection from the grid is the three-phase grid faults at the point common coupling (PCC) e.g. the voltage dip. The use of a Static Synchronous Compensator (STATCOM) which is from the family of Flexible AC Transmission S...
ver más
|
|
|
|
|
|
|
Sana Toumi, Yassine Amirat, Elhoussin Elbouchikhi, Zhibin Zhou and Mohamed Benbouzid
This article deals with the techno-economic optimal sizing of a tidal stream turbine (TST)?battery system. In this study, the TST system consists of a turbine rotor and a permanent magnet synchronous generator (PMSG) associated with a three-phase convert...
ver más
|
|
|
|
|
|
|
George K. Adam, Nikos Petrellis, Panagiotis A. Kontaxis and Tilemachos Stylianos
The progress of embedded control systems in the last several years has made possible the realization of highly-effective controllers in many domains. It is essential for such systems to provide effective performance at an affordable cost. Furthermore, re...
ver más
|
|
|
|
|
|
|
Ashish Shrestha, Roshan Kattel, Manish Dachhepatic, Bijen Mali, Rajiv Thapa, Ajay Singh, Diwakar Bista, Brijesh Adhikary, Antonis Papadakis and Ramesh Kumar Maskey
The issue of unintentional islanding in grid interconnection still remains a challenge in grid-connected, Distributed Generation System (DGS). This study discusses the general overview of popular islanding detection methods. Because of the various Distri...
ver más
|
|
|
|
|
|
|
Jinzhu Shi, Lihui Yang and Hao Yang
As a common interface circuit for renewable energy integrated into the power grid, the inverter is prone to work under a three-phase unbalanced weak grid. In this paper, the instability of grid-connected inverters under the unbalanced grid condition is i...
ver más
|
|
|
|
|
|
|
Mohamed Tanta, J. G. Pinto, Vitor Monteiro, Antonio P. Martins, Adriano S. Carvalho and Joao L. Afonso
This paper presents a deadbeat predictive current control methodology to reduce the circulating currents in a modular multilevel converter (MMC) when it operates as a rail power conditioner (RPC) in a conventional railway system-based V/V connection. For...
ver más
|
|
|
|
|
|
|
Amit Pandey
Harmonics plays important role in the function of the power system network. Hence, the harmonics improvement will increase the performance of power system equipment?s. This paper presents the design and implementation of distribution static compensator (...
ver más
|
|
|
|
|
|
|
Roberto Benato
The author has already presented some papers which allow studying cable systems by means of the multiconductor cell analysis (MCA). This method considers the cable system in its real asymmetry without simplified and approximated hypotheses. The multicond...
ver más
|
|
|
|
|
|
|
Surasit Songma, Theera Sathuphan and Thanakorn Pamutha
This article examines intrusion detection systems in depth using the CSE-CIC-IDS-2018 dataset. The investigation is divided into three stages: to begin, data cleaning, exploratory data analysis, and data normalization procedures (min-max and Z-score) are...
ver más
|
|
|
|
|
|
|
Unai Atutxa, Igor Baraia-Etxaburu, Víctor Manuel López, Fernando González-Hernando and Alejandro Rujas
Aircraft electrification requires reliable, power-dense, high-efficient, and bidirectional rectifiers to improve the overall performance of existing aircrafts. Thus, traditional bulky passive rectifiers must be substituted by active rectifiers, satisfyin...
ver más
|
|
|
|
|
|
|
|
Aleksander Suti, Gianpietro Di Rito and Roberto Galatolo
The reliability enhancement of electrical machines is one of the key enabling factors for spreading the full-electric propulsion to next-generation long-endurance UAVs. This paper deals with the fault-tolerant control design of a Full-Electric Propulsion...
ver más
|
|
|
|
|
|
|
Piyapath Siratarnsophon, Vinicius C. Cunha, Nicholas G. Barry and Surya Santoso
The capability of routing power from one phase to another, interphase power flow (IPPF) control, has the potential to improve power systems efficiency, stability, and operation. To date, existing works on IPPF control focus on unbalanced compensation usi...
ver más
|
|
|
|
|
|
|
Ultra-high voltage direct current (UHVDC) systems under hierarchical connection schemes (HCSs) linked to AC grids with different voltage levels (500 and 1000 kV) have been a great concern for power utilities to transfer bulk power. They have some operati...
ver más
|
|
|
|