Inicio  /  ChemEngineering  /  Vol: 4 Par: 3 (2020)  /  Artículo
ARTÍCULO
TITULO

Ammonia Removal Using Biotrickling Filters: Part A: Determination of the Ionic Nitrogen Concentration of Water Using Electrical Conductivity Measurement

Éric Dumont    
Solène Lagadec    
Nadine Guingand    
Laurence Loyon    
Abdeltif Amrane    
Valérie Couroussé and Annabelle Couvert    

Resumen

It is emphasized that a generalized relationship can be used to predict the ionic nitrogen concentration (i.e., sum of ammonium NH4+, nitrite NO2- and nitrate NO3-) of the scrubbing liquid in a biotrickling filter treating ammonia emissions by measuring the electrical conductivity (EC) of the water directly. From measurements carried out on different water samples from six biotrickling filters in operation in pig husbandries, the generalized relationship is: S([NH4+]+[NO2-]+[NO3-]) g N/L = 0.22 EC mS/cm. This equation is valid provided the fresh water feeding the biotrickling filter has a low electrical conductivity (<1 mS cm-1). Moreover, since ammonium, nitrite and nitrate ions are the ultra-majority ions in the liquid phase, the balance between NH4+ and (NO2- + NO3-) was confirmed, and consequently the relationship NH4+ = 0.11 EC mS/cm can also be applied to determine the ammonium concentration from the EC. As a result, EC measurement could be applied extensively to monitor operating biotrickling filters worldwide and used to determine ammonia mass transfer in real time, keeping in mind that the accuracy of the generalized relationship is ±20%.

 Artículos similares