Redirigiendo al acceso original de articulo en 24 segundos...
Inicio  /  Water  /  Vol: 15 Par: 21 (2023)  /  Artículo
ARTÍCULO
TITULO

Numerical Study on the Influence of Combined Rectification Facilities on the Flow in the Forebay of Pumping Station

Xiaobo Zheng    
Pengli Zhang    
Wenjing Zhang    
Yue Yu and Yaping Zhao    

Resumen

The flow pattern of the forebay of the pumping station has a considerable effect on the operating efficiency and stability of the pump unit. A good forebay flow pattern can enable the pump unit to improve efficiency and operating conditions. This study takes a large pumping station as the research object and considers two rectification schemes, namely, a single bottom sill and a ?bottom sill + diversion pier?. Without rectification facilities under different start-up schemes, the forebay flow pattern after the addition of rectification facilities is calculated, and the influence of single and combined rectification facilities is analyzed. Results show large-scale undesirable flow structures such as backflow and vortex in the forebay of the original design that without rectification facilities and uneven flow distribution occurs in the operating unit. The addition of a bottom sill in the forebay can control the central water beam from the water diversion pipe. The flow is divided to spread to both sides of the forebay and can be rectified twice after installing the diversion piers. The combined rectifier facility of ?bottom sill + diversion pier? is beneficial to disperse incoming flow and make the flow distribution of each unit more uniform. The backflow and vortex inside the forepond are basically eliminated, and the flow state of the forepond is significantly improved.